Given a 12-bit A/D converter operating over a voltage range from ????5 V to 5 V, how much does the input voltage have to change, in general, in order to be detectable

User Macbert
by
3.9k points

1 Answer

4 votes

Answer:

2.44 mV

Step-by-step explanation:

This question has to be one of analog quantization size questions and as such, we use the formula

Q = (V₂ - V₁) / 2^n

Where

n = 12

V₂ = higher voltage, 5 V

V₁ = lower voltage, -5 V

Q = is the change in voltage were looking for

On applying the formula and substitutiting the values we have

Q = (5 - -5) / 2^12

Q = 10 / 4096

Q = 0.00244 V, or we say, 2.44 mV