At steady state, air at 200 kPa, 325 K, and mass flow rate
of 0.5 kg/s enters an insulated duct having differing inlet
and exit cross-sectional areas. The inlet cross-sectional area is
6 cm26cm
2. At the duct exit, the pressure of the air is 100 kPa and the velocity is 250 m/s. Neglecting potential energy
effects and modeling air as an ideal gas with constant cp=1.008 kJ/kg⋅Kc
p =1.008kJ/kg⋅K, determine
(a) the velocity of the air at the inlet, in m/s.
(b) the temperature of the air at the exit, in K.
(c) the exit cross-sectional area, in cm2
(a) the velocity of the air at the inlet, in m/s.
(b) the temperature of the air at the exit, in K.
(c) the exit cross-sectional area, in cm