31.7k views
0 votes
A HSS152.4 × 101.6 × 6.4 structural steel [E = 200 GPa] section (see Appendix B for crosssectional properties) is used as a column with an actual length of 6 m. The column is supported only at its ends and it may buckle in any direction. If a factor of safety of 2 with respect to failure by buckling is specified, determine the maximum safe load for the column for the following end conditions:

(a) pinned-pinned
(b) fixed-free
(c) fixed-pinned
(d) fixed-fixed

User MBlanc
by
3.2k points

1 Answer

2 votes

Answer:

(a) 126.66 kN (b) 31.665 kN (c) 258.49 kN (d) 506.64 kN

Step-by-step explanation:

Solution

Given

A HSS152.4 × 101.6 × 6.4 structural steel is used as a column

Actual length of the column , L= 6 m

The elasticity modules, E = 200 GPa

The factor of safety with respect to failing buckling . F.S =2

Geometric properties of structural steel shapes for, A HSS152.4 × 101.6 × 6.4

the moment of inertial about y axis Iy =4 .62 * 10^ 6 mm ^4

For

(a) If the end condition is pinned - pinned

The effective length factor, K =1

The critical buckling load , Pcr = π²EI/(KL)²

Pcr = π² * 200 * 10 ^3 * 4.62 * 10 ^6/( 1* 6* 10 ^3)

= 253319.85N

= 253.32N

The maximum safe load , Pallow = 253.32 /2 = 126.66kN

hence, the maximum safe for the column is 126.66kN

(b)If the end condition is fixed free-free

the effective length factor, K= 2

The critical buckling load , Pcr = π²EI/(KL)²

Pcr = π² * 200 * 10 ^3 * 4.62 * 10 ^6/( 2 * 6 * 10 ^3)²

= 63329.96N

=63.33kN

The maximum safe load, P allow = Pcr/F.S

P allow = 63.33/2

31.665 kN

Therefore the maximum safe for the column is 31.665 kN

(c) If the end condition is fixed- pinned

The effective length factor K =0.7

The critical buckling load , Pcr = π²EI/(KL)²

Pcr = π² * 200 * 10 ^3 * 4.62 * 10 ^6/( 0.7 * 6 * 10 ^3)²

=516979.2 8N

=516.98 kN

The maximum safe load, P allow = Pcr/F.S

P allow = 516.98 kN/2

=258.49 kN

Therefore the maximum safe for the column is 258.49 kN

(d) If the end condition is fixed -fixed

The effective factor, K =0.5

The critical buckling load , Pcr = π²EI/(KL)²

Pcr = π² * 200 * 10 ^3 * 4.62 * 10 ^6/( 0.5 * 6 * 10 ^3)²

=1013279.4 N

=1013.28 kN

The maximum safe load, P allow = Pcr/F.S

P allow = 1013.28 / 2

= 506.64 kN

P allow = 506.64 kN

Therefore the maximum safe for the column is 506.64 kN

User Spina
by
3.0k points