48.7k views
1 vote
8 A static load test has been conducted on a 60 ft long, 16 in square reinforced concrete pile which has been driven from a barge through 20 ft of water, then 31 ft into the underlying soil. Telltale rods A and B have been embedded at points 30 ft and 59 ft from the top of the pile, respectively. The data recorded at failure was as follows: Load at head = 139,220 lb, settlement at head = 1.211 in, settlement of telltale rod A = 1.166 in,settlement of telltale rod B = 1.141 in. Use the data from telltale rod A to compute the modulus of elasticity of the pile, then use this value and the remaining data to compute q′n and the average fn value.

User Grizzly
by
4.3k points

1 Answer

2 votes

Answer:

Modulus of Elasticity = 4.350×10⁶ lb/in²

q'n = 60.33 lb/in²

Side friction = 6.372 lb/in²

Step-by-step explanation:

See workings in picture below.

8 A static load test has been conducted on a 60 ft long, 16 in square reinforced concrete-example-1
User Opoe
by
4.3k points