13.8k views
2 votes
A converging - diverging frictionless nozzle is used to accelerate an airstream emanating from a large chamber. The nozzle has an exit area of 30 cm^2 and a throat area of 15 cm^2. If the ambient pressure surrounding the nozzle is 101 kPa and the chamber temperature is 500 K, calculate the following:

A) Minimum chamber pressure to choke the nozzle
B) Mass flow rate for a chamber pressure of 400 kPa

2 Answers

4 votes

Answer:

a. 617.958kpa

b. 1.351kg/sec

Step-by-step explanation:

Please see attachment for step by step guide.

A converging - diverging frictionless nozzle is used to accelerate an airstream emanating-example-1
A converging - diverging frictionless nozzle is used to accelerate an airstream emanating-example-2
A converging - diverging frictionless nozzle is used to accelerate an airstream emanating-example-3
User Phortuin
by
4.1k points
2 votes

Answer:

A) Minimum chamber pressure to choke the nozzle is 107.772kpa

B) Mass flow rate for a chamber pressure of 400 kPa is 1.0846 kg / s

Step-by-step explanation:

Find attached the explanation

A converging - diverging frictionless nozzle is used to accelerate an airstream emanating-example-1
User Yorick
by
5.0k points