Answer:
nf=1.11 (Goodman criterion)
ny=2.41 (factor of safety for fatigue)
Step-by-step explanation:
From the table A-20 Deterministic ASTM minimum tensile and yield strengths for HR and CD steels, we have approximately:
Sut=120 kpsi
Sy=66 kpsi
Due Sut<1400 Mpa, the endurance limit is:
The surface condition modification factor is:
The effective diameter is:
The size factor is:
The endurance limit at critical location is:
From Figure A-15-15 chart, the Kf = 2.1
The notch sensitivity is:
The fatigue stress is:
The moment of inertia is:
The maximum stress is:
The mean stress is:
The alternate stress is:
The fatigue factor using Goodman is:
nf=1.11
the factor of safety is: