Final answer:
When preparing a site for electrode placement for Holter monitoring, a medical assistant should cleanse the site, shave any body hair, and apply electroconductive gel for accurate recording.
Step-by-step explanation:
When preparing a site for electrode placement for Holter monitoring, the medical assistant should take the following actions:
- Cleanse the site with chlorhexidine: This helps remove any dirt or bacteria on the skin, ensuring a clean surface for electrode placement.
- Shave any body hair at the site: Body hair can interfere with the proper adhesion of the electrodes, so it is important to remove it.
- Apply electroconductive gel to the site: The gel enhances the contact between the skin and the electrodes, allowing for accurate recording of the electrical signal.
- Marking the site with a permanent marker is not necessary for electrode placement.