Answer: The required yield strength YS is 350 MPa
Explanation:
Given that;
for an annealed 65 - 45- 12 cast iron structural member,
indenter used : WC ball
Diameter of the indenter D = 10 mm
Diameter of impression d = 4.48
Load = 3000 kg
Now, the Brinell Hardness Number BHN can be determined by using the following formula;
BHN = 2P / (πD[ D - √( D² - d²))
we substitute
BHN = 2(3000) / (π×10[ 10 - √( 10² - 4.48²))
BHN = 6000 / 10π[ 10 - 8.9403]
BHN = 6000 / 33.2914
BHN = 180.22 ≈ 180
Corresponding values to BHN = 180
Yield Strength Y.S = 350 MPa