Answer:
Answered
Step-by-step explanation:
COP is the coefficient of performance of refrigerator and Heat pump
COP of refrigerator is given by
cooling effect/work input =
![(Q_L)/(W_(in))](https://img.qammunity.org/2020/formulas/engineering/college/sawwlqlh5c9vruisxfdbmilph8qgg47ofb.png)
And for ideal refrigeration cycle
COP=
![(T_L)/(T_H-T_L)](https://img.qammunity.org/2020/formulas/engineering/college/9w07kj7uquamuztanhl2lb790c01lz8eau.png)
COP of heat pump is given by
Heating effect/ work input =
![(Q_H)/(W_(in))](https://img.qammunity.org/2020/formulas/engineering/college/jmyguf9pmugywzyoj7cemtl3g4b96xljaz.png)
And for ideal Heat pump cycle
COP=
![(T_H)/(T_H-T_L)](https://img.qammunity.org/2020/formulas/engineering/college/yjqojvhjc2t8kqdxy7vltrla2f4cnc1yaf.png)
Now, we can conclude that
![COP_(HP)= COP_(R)+1](https://img.qammunity.org/2020/formulas/engineering/college/ttoop5hc3sgznb57avalazhcnci2q8y2fq.png)