Answer:
average emf induced in the coil is 1.57 x
V
Step-by-step explanation:
Given data
n = 10 turns per centimeter = 1000 m^-1
N = 5
cross-sectional area A = 5.0 cm2 = 5.0 x 10^-4 m²
current = 0.25 A
to find out
average emf induced in the coil
solution
we will find emf by the given formula
emf = - (μ×N×n×A×ΔI ) / t ..................1
here
μ = 4π x 10^-7 and
N = 10
n = 1000
A = 5.0 x 10^-4
ΔI = 0.25
t = 0.050
put all value in equation 1
emf = - (μ×N×n×A×ΔI ) / t
emf = - (4π x 10^-7 ×5 ×1000× 5.0 x 10^-4 × 0.25 ) / 0.050
emf = 1.57 x
V
average emf induced in the coil is 1.57 x
V