Answer:
Power consume by compressor=113,726.87 KW
Step-by-step explanation:
Given:
![P_(1)=100KPa ,V_(1)=200 m/s,T_(1)=283 K, A_(1) =2m^2](https://img.qammunity.org/2020/formulas/engineering/college/knwvyy1zm69gjefy5imxvndw1y7zteb27z.png)
![P_(2)=2000KPa ,T_(2)=513 K,A_(2)=0.5m^2](https://img.qammunity.org/2020/formulas/engineering/college/2jk8gk46i6o1tueo9dnlhyba09k204quur.png)
Actually compressor is an open system, so here we will use first law of thermodynamics for open system .
We know that first law of thermodynamics for steady flow
![h_(1)+(V_(1) ^(2) )/(2)+Q=h_(2)+(V_(2) ^(2) )/(2)+W](https://img.qammunity.org/2020/formulas/engineering/college/9co86f2il49hk548971525qkjmi12o9s60.png)
We know that
and we take the air as ideal gas.
System is in steady state then mass flow rate in =mass flow rate out
Mass flow rate=
![density* area* velocity](https://img.qammunity.org/2020/formulas/engineering/college/dapptelmkvzkad63wde6pdjqxquxfh07wa.png)
So mass flow rate =
,
![\rho =(P)/(RT)](https://img.qammunity.org/2020/formulas/engineering/college/e33bubb74f1wsdeq9gaqfu8r095agt57rn.png)
=1.23×200×2 Kg/s
=541.17 Kg/s
![\rho _(1)V_(1)A_(1)=\rho _(2)V_(2)A_(2)](https://img.qammunity.org/2020/formulas/engineering/college/pmea4wrb6cfdrzpqif2l7f88djjdihp2jr.png)
,
![\rho =(P)/(RT)](https://img.qammunity.org/2020/formulas/engineering/college/e33bubb74f1wsdeq9gaqfu8r095agt57rn.png)
=80.07 m/s
Enthalpy of ideal gas h=
![C_(p)* T](https://img.qammunity.org/2020/formulas/engineering/college/i5nenep1qddu5ab2ppmyq6c4yy9u3jf083.png)
So
![h_(1)=1.005*283=284.41(Kj)/(Kg)](https://img.qammunity.org/2020/formulas/engineering/college/esycf7o6hu8saay1rir16bu6xc28tpsmkt.png)
![h_(2)=1.005*513=515.56(Kj)/(Kg)](https://img.qammunity.org/2020/formulas/engineering/college/t9i3k27z03zy4m8f5focvbtakcuegwk37x.png)
Now by putting the values
![284.41+(220 ^(2) )/(2000)+Q=515.56+(80.07 ^(2) )/(2000)+W](https://img.qammunity.org/2020/formulas/engineering/college/1ccbot82w5cud06bejunvxqp5yvwaf8w9k.png)
Here Q=0 because heat transfer is zero here.
W= -210.15 KJ/kg
So power consume by compressor=541.17×210.15
=113,726.87 KW