Answer:
11.65kW
Step-by-step explanation:
Step one:
given data
from the table for R-134a
For the given pressure state the following data were extracted.
s=0.94202kJ/kg.K
h1=241.14kJ/kg
∝1=0.12355m^3/kg
By interpolation, the final enthalpy and pressure with data from the table of R-134a
h2=277.12kJ/kg
The minimum power output is then determined from the energy balance
W=m(h2-h1)
W=V1/∝1(h2-h1)
W=2.4/60/0.12355(277.12-241.14)
W=0.04/0.12355(35.98)
W=0.3237(35.98)
W=11.65kW Approx.
The minimum power output of the compressor is 11.65kW