9.1k views
0 votes
Determine the complex power, apparent power, average power absorbed, reactive power, and power factor (including whether it is leading or lagging) for a load circuit whose voltage and current at its input terminals are given by:

a. v(t)= 100cos(377t - 30°) V
i(t)= 2.5cos(377t- 60°) A

b. Vrms= 110e^j60 , Irms= 3e^j45 A

User Brennon
by
5.0k points

1 Answer

2 votes

Answer:

A) complex power = apparent power = ( 108.253 + 62.5 i ) VA

active power = 108.25 watts

reactive power = 62.5 VAR'S

power factor = cos ∅ = cos 30° = 0.866 ( lagging )

also ; current lags voltage by 30°

B) your question is not well written hence no answer

Step-by-step explanation:

A) v(t) = 100 cos (377t - 30° ) v

Vrms =
(100)/(√(2) ) ∠ -30°

I(t) = 2.5cos(377t- 60°) A

Irms =
(2.5)/(√(2) ) ∠ -60°

determine complex power apparent power . ...... power factor

Note : complex power = apparent power

=( Irms ) * Vrms

= (
(2.5)/(√(2) ) ∠ -60° ) * (
(100)/(√(2) ) ∠ -30° )

= 125 ∠ 30°

= ( 108.253 + 62.5 i ) VA ( complex power )

active power = 108.25 watts

reactive power = 62.5 VAR'S

power factor = cos ∅ = cos 30° = 0.866 ( lagging )

current lags voltage by 30°

User Josue Espinosa
by
4.8k points