81.7k views
5 votes
An electrical appliance will not work unless component QK does. Component QK's reliability is 0.95. Every other part of the appliance is 100% reliable. What would the reliability of the appliance be if a backup QK were added?

a.95

b.9795

c.9205

d.9975

e.9025

User Eric Mutta
by
5.2k points

1 Answer

4 votes

Answer:

d.9975

Step-by-step explanation:

The computation of the reliability of the appliance in the case when the backup QK were added is shown below:

= ( 1 - QK's reliability) × QK's reliability + QK's reliability

= (1 - 0.95) × 0.95 + 0.95

= 0.05 × 0.95 + 0.95

= 0.0475 + 0.95

= 0.9975

Hence, the correct option is d. 0.9975

The same is to be considered

Also we simply applied the above formula so that the correct percentage could come

User PatNowak
by
5.0k points