Answer:
Technician B
Step-by-step explanation:
Both AWG and metric are sized by cross-sectional area.
Technician A is wrong: 12 gauge wire is larger diameter rated for 20 amps in free air. 18 awg is smaller diameter and typically used for speaker wiring, Class II or low voltage and sub-circuits within appliances.