In many parts of the country, the wiring method in unfinished basements is ____ in the ceiling and EMT on the walls for receptacles and switches.

User Casey Chow
by
6.3k points

2 Answers

2 votes

The typical wiring method in unfinished basements uses nonmetallic sheathed cable in the ceiling and EMT on the walls. This provides a balance between cost-efficiency and protection against physical damage, while EMT on walls helps protect wiring in accordance with NEC standards. The wiring practices ensure electrical safety, complementing the three-wire system that significantly reduces the risk of electric shock.

In many parts of the country, the wiring method in unfinished basements typically employs nonmetallic sheathed cable (often referred to as NM, Romex, or NM-B cable) in the ceiling and Electrical Metallic Tubing (EMT) on the walls for receptacles and switches. This practice balances cost and protection, as NM cable is less expensive and easier to install overhead, while EMT provides robust protection against physical damage for visible wiring along walls. Furthermore, the use of EMT is aligned with the requirements of the National Electrical Code (NEC) for areas where cables are exposed to potential harm.

The importance of proper wiring cannot be overstated, as it ensures electrical safety within the dwelling. When considering the three-wire system, which connects the neutral wire to the earth, it ensures zero volts at the user location, providing an alternative return path through the earth and grounded appliance cases. This system is enhanced by circuit breakers or fuses that protect against overcurrent by interrupting the circuit in instances of thermal overload, such as when a live/hot wire with worn insulation contacts a metallic case. It also explains why modern appliances with two-prong plugs usually have non-conducting cases or are doubly insulated for additional safety.

User Carel
by
6.3k points
1 vote

The correct answer to this open question is the following.

Although there are no options provided, we can answer the following.

In many parts of the country, the wiring method in unfinished basements is non-metallic-sheated cable in the ceiling and EMT on the walls for receptacles and switches.

This cable is flexible and is covered by plastic sheathing to protect the conductors that are insulated. In 1922, the company Romex created this type of cable. The use of this material became common in the 1960s when woven rayon was replaced by plastic. Architects started to use this Non-Metallic cable in American houses for electrical wiring. As it was hidden, it did not mess with the house decoration. Another great advantage of its popularity is that it is non-expensive.