22.5k views
0 votes
An array of solar panels produces 9.35 A of direct current at a potential difference of 195 V. The current flows into an inverter that produces a 60 Hz alternating current with Vmax = 166V and Imax = 19.5A.

A) What rms power is produced by the inverter?
B) Use the rms values to find the power efficiency Pout/Pin of the inverter.

User Tony Rad
by
5.4k points

1 Answer

4 votes

Answer:

(A). 1620 watt.

(B).0.8885.

Step-by-step explanation:

So, we are given the following data or parameters or information which is going to assist or help us in solving this particular Question or problem. So, we have;

Current = 9.35A, direct current at a potential difference of 195 V, frequency of the inverter = 60 Hz alternating current, alternating current with Vmax = 166V and Imax = 19.5A.

(A). The rms power is produced by the inverter = (19.5 /2 ) × 166 = 1620 watt(approximately).

(B). the rms values to find the power efficiency Pout/Pin of the inverter.

P(in) = 195 × 9.35 = 1823.3 watt.

Thus, the rms values to find the power efficiency Pout/Pin of the inverter = 1620/1823.3 = 0.88852324146441793 = 0.8885.