209k views
3 votes
Air at 1 atm, 158C, and 60 percent relative humidity is first heated to 208C in a heating section and then humidified by introducing water vapor. The air leaves the humidifying section at 258C and 65 percent relative humidity. Determine (a) the amount of steam added to the air, and (b) the amount of heat transfer to the air in the heating section.

User Dude
by
4.4k points

2 Answers

3 votes

Answer: right side B

Step-by-step explanation:

User Michael Sheaver
by
4.8k points
2 votes

Answer:

A. the amount of steam added to the air s 0.065kgH20/kg dry air

B.the amount of heat transfer to the air in the heating section is 5.1KJ/Kg of dry air

Step-by-step explanation:

Pls see attached file