Answer:
The correct option is;
B. Neither Technician A nor B
Step-by-step explanation:
A performance test is meant to determine the proper functioning of the air conditioning system for fault finding where repair is required
While the engine is powered off it is expected that to have the same pressure or equal pressures in the low-side and high-side pressure and have a pressure expected for a given ambient temperature, such that, as an example, a system with R134a should have a pressure slightly more than 71 psi. at 70°F
Therefore, neither technicians A nor B is correct as the ambient temperature is important for performance testing and high-side and low-side pressures should be equal when the engine is powered off.