2. An aluminum (E = 70 GPa) tube of length 8-m is used as a simply supported column carrying a 1.2 kN axial load. If the outer diameter of the tube is 50 mm, compute the inner diameter that would provide a safety factor of 2 on buckling.

User Deplake
by
5.4k points

1 Answer

2 votes

Answer:

1211 N.

Step-by-step explanation:

Okay, we are given the following data or parameters or information in the question above;

=> "aluminum (E = 70 GPa) tube of length 8-m.

=> "The aluminum is used as a simply supported column carrying a 1.2 kN axial load"

The axial load to provide a factor of safety of 2 against buckling =[ (22/7)^2 × 224348 × 1000 × 70] ÷ (8 × 1000)^2 × 2.

The axial load to provide a factor of safety of 2 against buckling = 1211 N.