Answer:
(a) Qh(dot)=600 kW, Qc(dot)=400 kW is an irreversible process.
(b) Qh(dot)=600 kW, Qc(dot)=0 kW is an impossible process.
(c) Qh(dot)=600 kW, Qc(dot)=200 kW is a reversible process.
Step-by-step explanation:
T(hot) = 1200k, T(cold) = 400
efficiency n = (Th - Tc ) / Tc
n = (1200 - 400) / 1200 = 0.667 (this will be the comparison base)
(a)
Qh = 600 kW, Qc = 400 kW
n = (Qh - Qc) / Qh ⇒ (600 - 400) / 600
n = 0.33
0.33 is less than efficiency value from temperature 0.67
∴ it is irreversible process
(b)
Qh = 600 kW, Qc = 0
n = (Qh - Qc) / Qh ⇒ (600 - 0) / 600 = 1
efficiency in any power cycle can never be equal to one.
∴ it is an impossible process.
(c)
Qh = 600 kW, Qc = 200 kW
n = (Qh - Qc) / Qh = (600 - 200) / 600
n = 0.67 (it is equal to efficiency value from temperature)
∴ it is a reversible process