Given Information:
Number of slots = 24
Number of turns = 40
Flux per pole = 0.060 Wb
Speed of rotation of magnetic field = 1800 rev/min
Required Information:
a) Frequency = ?
b) Phase and Terminal voltage = ?
Answer:
a) Frequency = 60 Hz
b) Phase voltage = 2560 V
Terminal voltage = 4434 V
Step-by-step explanation:
(a)What is the frequency of the voltage produced in this winding?
The relation between frequency of the voltage produced and the speed of rotation of magnetic field is given by

Where n is the speed of rotation of magnetic field and P is the number of poles in the winding.

(b)What are the resulting phase and terminal voltages of this stator?
The phase voltage is given by

Where N is the number of turns, Ф is the flux per pole and f is the frequency calculated in part a.

There are total 24 slots so each phase has 24/3 = 8 slots
We know that the number of poles are 4 so that means each phase has 4 sets of coils.
So the voltage in each phase is
Vp = 4*640
Vp = 2560 V
Since it is a Y-connected machine, The terminal voltage is will be