Answer:
Step-by-step explanation:
Half width - 3.75 m
Rainfall intensity - 90 mm/hr
Longitudinal slope - 0.75%
Cross slope - 2.25%
Allowable limit of gutter flow, Q road = (Design constant x Intensity of rain x Area) / 360
= (0.91×90×(9×L1×10∧-4)/360 = 0.000204 L1
Using the standard design chart, allowable limit of gutter flow =0.018 m3/s
Therefore,0.018 = 0.000204 L1
L1 = 0.018 / 0.000204 = 88.24
Inlet spacing to be adapted is 88m