The air velocity in the duct of a heating system is to be measured by a Pitot-static probe inserted into the duct parallel to the flow. The differential height between the water columns connected to the two outlets of the probe is 0.126 m.Take the density of water to be 1000 kg/m3. The gas constant of air is R = 0.287 kPa-m3/kg-K.The air temperature and pressure in the duct are 352 K and 98 kPa, respectively.

1 Answer

4 votes

Answer:

Flow velocity

50.48m/s

Pressure change at probe tip

1236.06Pa

Step-by-step explanation:

Question is incomplete

The air velocity in the duct of a heating system is to be measured by a Pitot-static probe inserted into the duct parallel to the flow. If the differential height between the water columns connected to the two outlets of the probe is 0.126m, determine (a) the flow velocity and (b) the pressure rise at the tip of the probe. The air temperature and pressure in the duct are 352k and 98 kPa, respectively

solution

In this question, we are asked to calculate the flow velocity and the pressure rise at the tip of probe

please check attachment for complete solution and step by step explanation

The air velocity in the duct of a heating system is to be measured by a Pitot-static-example-1
User KallDrexx
by
4.9k points