Technician A says that the accumulator is on the high-pressure side of the refrigerant system. Technician B says that the receiver-drier is attached to the evaporator outlet on the refrigerant system. Who is correct?

User Zilchonum
by
6.8k points

1 Answer

7 votes

Question:

The options are

a. Technician A only

b. Technician B only

c. Both A and B

d. Neither A nor B

Answer:

The correct option is

d. Neither A nor B

Step-by-step explanation:

Here, we note that to locate the receiver/driers we look at the high-pressure side of refrigerant system normally around the tubes in between the expansion valve outlet and the condenser outlet and connected to the condenser.

While the accumulator can be found, attached to the evaporator outlet within the low pressure side of the refrigerant system.

Therefore, neither Technician A nor B is correct.