172k views
0 votes
Two reversible cycles operate between hot and cold reservoirs at temperature TH and TC, respectively. If one is a power cycle and the other is a heat pump cycle, what is the relation between the coefficient of performance of the heat pump cycle and the thermal efficiency of the power cycle?

1 Answer

3 votes

Answer:


COP_(HP) = (1)/(\eta_(th))

Step-by-step explanation:

The coefficient of performance of the reversible heat pump is:


COP_(HP) = (T_(H))/(T_(H)-T_(C))


COP_(HP) = (1)/(1-(T_(C))/(T_(H)) )

The thermal efficiency of the reversible power cycle is:


\eta_(th) = 1 - (T_(C))/(T_(H))

After a quick comparison between both expressions, the following relation is found:


COP_(HP) = (1)/(\eta_(th))

User Ryan Salmons
by
5.0k points