59.7k views
1 vote
Carbon dioxide used as a natural refrigerant flows through a cooler at 10 MPa, which is supercritical, so no condensation occurs. The inlet is at 220°C and the exit is at 50°C. Find the specific heat transfer.

User Prashast
by
4.8k points

2 Answers

1 vote

Answer:

Answer is -286.78 kJ/kg

Refer below.

Step-by-step explanation:

Refer to the pictures for brief explanation.

Carbon dioxide used as a natural refrigerant flows through a cooler at 10 MPa, which-example-1
Carbon dioxide used as a natural refrigerant flows through a cooler at 10 MPa, which-example-2
User Anamarie
by
5.6k points
2 votes

Answer:

The answer which is a calculation can be found as an attached document

Step-by-step explanation:

Carbon dioxide used as a natural refrigerant flows through a cooler at 10 MPa, which-example-1
Carbon dioxide used as a natural refrigerant flows through a cooler at 10 MPa, which-example-2
User Eluong
by
5.7k points