Answer:
The blue ring around was caused by the reaction of the oxidase reagent with the filter paper
Step-by-step explanation:
Generally the student must have performed filter paper method of oxidative test. Based on standard, when the colony was applied to the filter paper, within 10 -30s a deep-blue or purple coloration should indicate oxidation, and catalysis of reduction by oxidase enzyme, to indicate the bacteria that produce the cytochrome oxidase.
However, when the reaction was left for long minutes, the oxidative reagents reacts with the paper based medium of the reaction. These reagents are tetramethyl-p-phenylenediamine ( which the filter paper was soaked in )and iodophenol. The oxidase enzyme catalyses tetramethyl-p-phenylenediamine to iodophenol; which gives the usual purple or blue coloration end products. However, when the reaction was left for long these reagents reacted with the filter paper to give dark blue ring around each of the microorganism.