Answer:
a) The laser device
b) The tape
Step-by-step explanation:
First, there is a need to understand what accuracy and precision mean.
Accuracy is the closeness of a measurement to its true (pre-determined) value.
Precision is the closeness of repeated measurements to each other.
Since 1 feet = 12 inches, then, 5 feet and 5.2 inches would be equivalent to 65.2 inches. This value represents the true value of my height.
The tape measured the height as 65 3/8, which is equivalent to 65.375 inches.
The laser device measured the height as 65.31.
Error = true value - measured value
Absolute error from the tape = 65.2 - 65.375
= -0.175 inches
Absolute error from laser device = 65.2 - 65.31
= -0.11
a) The magnitude of error from the tape is more than that of the laser device. Hence, the laser device is said to be more accurate.
b) Even though there were just single readings from both instruments, the tape can be read to the nearest 1/8 of an inch and as such, can give more precisive measurements than the laser device.