Answer:
hello the figure attached to your question is missing attached below is the missing diagram
answer :
i) 1.347 kW
ii) 1.6192 kW
Step-by-step explanation:
Attached below is the detailed solution to the problem above
First step : Calculate for Enthalpy
h1 - hf = -3909.9 kJ/kg ( For saturated liquid nitrogen at 600 kPa )
h2- hg = -222.5 kJ/kg ( For saturated vapor nitrogen at 600 kPa )
second step : Calculate the rate of heat transfer in boiler
Q1-2 = m( h2 - h1 ) = 0.008( -222.5 -(-390.9) = 1.347 kW
step 3 : find the enthalpy of superheated Nitrogen at 600 Kpa and 280 K
from the super heated Nitrogen table
h3 = -20.1 kJ/kg
step 4 : calculate the rate of heat transfer in the super heater
Q2-3 = m ( h3 - h2 )
= 0.008 ( -20.1 -(-222.5 ) = 1.6192 kW