180k views
11 votes
The output of a first order transducer is to be connected to a signal conditioner which also has first order dynamic characteristics. The transducer has known time constant of x milliseconds and static sensitivity of xx V/kPa while the signal conditioner has a time constant of y milliseconds and a static sensitivity of yy V/V. Determine the steady state response of this measurement system to an input signal of the form: P(t)=(A+B*sin(w*t) ) kPa.

1 Answer

2 votes

Answer:

hello your question is poorly written attached below is the correct question

answer : y(t) = 1.5 + 0.025 sin( 600t - 0.259 ) v

Step-by-step explanation:

Given data:

Time constant = 5msec

static sensitivity = 0.05 v/°c

f = 100 hz

ε = 0.8

T(t) = ( 30 + 2.5 sin600t )°C

attached below is a detailed solution to the question above

The output of a first order transducer is to be connected to a signal conditioner-example-1
The output of a first order transducer is to be connected to a signal conditioner-example-2
The output of a first order transducer is to be connected to a signal conditioner-example-3
User Pjco
by
4.3k points