104k views
3 votes
Ketone C=O signals usually appear at 1720 cm⁻¹. If a C=O is present in a molecule with ring strain, how does this value change in comparison?

a. Shifts to higher wavenumber
b. Shifts to lower wavenumber
c. Remains unchanged
d. Disappears

User Kimpoy
by
8.3k points

1 Answer

5 votes

Final answer:

The presence of ring strain in a molecule causes the C=O signal to shift to a lower wavenumber.

Step-by-step explanation:

The presence of ring strain in a molecule will cause the C=O signal to shift to a lower wavenumber. This means that the absorption peak will appear at a lower frequency compared to the normal C=O signal at 1720 cm⁻¹. The shift occurs because the ring strain affects the bonding structure of the molecule, causing a change in the energy required for the C=O bond to vibrate.

User DMb
by
8.3k points