122k views
5 votes
While inspecting a cryogenic liquid cylinder prior to use, you notice the outside jacket of the container is cold. What may this indicate? ​

User JeffLL
by
7.7k points

1 Answer

3 votes

Step-by-step explanation:

The evacuated (vacuum) space between the inside and the outside may have been compromised and air ( or the cryogenic fluid) has gotten in between the walls so the cylinder will not work very well any longer

User Jahi
by
8.1k points