3 votes
2. Fracture mechanics. A structural component in the form of a wide plate is to be fabricated from a steel alloy that has a plane- strain fracture toughness of 98.9 MPa √ m and a yield strength of 860 MPa . The flaw size resolution limit of the flaw de tection appa ratus is 3.0 mm . If the design stress is one- half the yield strength and the value of Y is 1.0, determine whether a critical flaw for this plate is subject to detection.

1 Answer

2 votes

Answer:

the critical flaw is subject to detection since this value of ac (16.8 mm) is greater than the 3.0 mm resolution limit.

Step-by-step explanation:

This problem asks that we determine whether or not a critical flaw in a wide plate is subject to detection given the limit of the flaw detection apparatus (3.0 mm), the value of KIc (98.9 MPa m), the design stress (sy/2 in which s y = 860 MPa), and Y = 1.0.


ac=1/\pi ((Klc)/(Ys) )^(2)\\ ac=1/\pi((98.9)/((1)(860/2)) )^(2)\\  ac=0.0168m\\ac=16.8mm

Therefore, the critical flaw is subject to detection since this value of ac (16.8 mm) is greater than the 3.0 mm resolution limit.