An 18.65-kW, 4-pole, 50-Hz, 3-phase induction motor has friction and windage losses of 2.5 percent of the output. The full-load slip is 4%. (a) Determine the friction and windage loss.

User Carolin
by
8.7k points

1 Answer

0 votes

Answer:

0.47 kW

Step-by-step explanation:


P_(out) = 18.65kW

The friction and windage losses is given to be 2.5% of
P_(out)

Therefore, the friction and windage losses
P_(fw) = (2.5)/(100) * 18.65 kW


P_(fw) = 0.025 × 18.65 kW


P_(fw) = 0.46625 kW


P_(fw) = 0.47 kW

The friction and windage loss of the induction motor is 0.47 kW