A multistage pump is required to deliver water to a head of 50 m at flow rate of 0.1 m^3/s. A motor rotating at 1800 rpm is available. Determine the optimal number of stages for the pump.

User Fgysin
by
7.2k points

1 Answer

2 votes

Answer:

number of stages for the pump is 4

Step-by-step explanation:

given data

water head Hm = 50 m

flow rate r = 0.1 m³/s

rotating N = 1800 rpm

to find out

optimal number of stages for the pump.

solution

we consider here specific speed does not exceed more than 82

so Ns formula will be

Ns =
(N√(r) )/(H^(3/4))

here Ns id 82 and N is rotating and r is flow rate

so

82 =
(1800√(0.1) )/(H^(3/4))

so H = 13.23 m

so

number of stage n is

nH = Hm

n =
(50)/(13.23)

n = 3.77 ≈ 4

so number of stages for the pump is 4

User Boxiom
by
7.6k points