15.9k views
3 votes
The Cv factor for a valve is 48. Compute the head loss when 30 GPM of water passes through the valve.

1 Answer

5 votes

Answer:

The head loss in Psi is 0.390625 psi.

Step-by-step explanation:

Fluid looses energy in the form of head loss. Fluid looses energy in the form of head loss when passes through the valve as well.

Given:

Factor cv is 48.

Flow rate of water is 30 GPM.

GPM means gallon per minute.

Calculation:

Step1

Expression for head loss for the water is given as follows:


c_(v)=(Q)/(√(h))

Here, cv is valve coefficient, Q is flow rate in GPM and h is head loss is psi.

Step2

Substitute 48 for cv and 30 for Q in above equation as follows:


48=(30)/(√(h))


{√(h)}=0.625

h = 0.390625 psi.

Thus, the head loss in Psi is 0.390625 psi.

User Joshua Welz
by
8.4k points