53.1k views
5 votes
A baby requires positive-pressure ventilation because she is not breathing (apneic), but she soon establishes spontaneous respirations and a heart rate over 100 beats per minute. Her oxygen saturation is lower than the target level when in room air, so you provide free-flow oxygen. What devices cannot reliably deliver free-flow oxygen?

1 Answer

3 votes

Answer: The device that cannot reliably deliver free-flow oxygen to the baby is the mask that is attached to self inflating bag. Some of the devices that can give free-flowing oxygen to the baby could be; a funnel, T-piece resuscitator, and tubing held in your hand that is up the baby's face.

The flow-inflating bag with a mask is what is needed to give free-flow oxygen, in replace of the mask attached to the self inflating bag.

User Patrine
by
7.7k points
Welcome to QAmmunity.org, where you can ask questions and receive answers from other members of our community.