76.2k views
1 vote
Technician A says that when a fuse has popped, it just needs to be replaced, since it performed its job. Technician B says that when a fuse has blown, the circuit needs to be diagnosed because the fuse was probably not the problem.

Who is correct?
A. Technician A
B. Technician B
C. Both Technician A and Technician B
D. Neither Technician A nor Technician B

2 Answers

3 votes

Answer: B) Technician B

Step-by-step explanation:

Technician B's statement is correct because when the bulb gets damaged, there are probable chances that the circuit needs to be diagnosed or repaired.

When the power overloads in the circuit or different voltage nodes of wires get interconnected with each other then, there is also chances of short circuit as well. So, that is why circuit needs to be repaired.

So, these might be the possible reasons for the bulb that get trip or fuses apart from the defect in the bulb itself.

User Jpen
by
5.6k points
2 votes

Answer:

Technician B

Step-by-step explanation:

Technician A says that when a fuse has popped, it just needs to be replaced, since it performed its job. Technician B says that when a fuse has blown, the circuit needs to be diagnosed because the fuse was probably not the problem. In the above case Technician B is correct because to the work of Fuse or circuit breakers( are tripped) is get blown away when excess of current is flowed in the circuit. So, there must a problem in in circuit it self that led to the melting of fuse. Therefore, we must diagnose the Circuit first.

User Krolth
by
5.8k points