Answer:
Step-by-step explanation:
A. False - blood tubing and filter should only be primed with the PRBC, not NS, but IV NS should be primed and ready for use in case of a transfusion reaction
B. False - KL identification/ verification should be made by 2 licensed personnel only
C. True - baseline VS should always be obtained prior to transfusion to monitor changes from the baseline which could signal a blood transfusion reaction
D. True - infusion should start 125ml/hour that is usually the standard rate
E. VS should be taken every 15 minutes in the first 30 minutes of infusion, if a transfusion reaction does occur it will occur within the first 15 to 30 of the transfusion that is why it’s monitored more frequently
F. False - Transfusion should be completed within 4 hours, unless otherwise ordered