194k views
2 votes
Lagrange multipliers have a definite meaning in load balancing for electric network problems. Consider the generators that can output xi megawatts, i = 1, 2, 3 each generator cost

Ci = 3xi + ( i /40) xi^2 i .

If the total power needed is 1000MW. What load balance (x1, x2, x3) minimizes cost?

1 Answer

7 votes

Answer:

The load balance
(x_1,x_2,x_3)=(545.5,272.7,181.8) Mw minimizes the total cost

Explanation:

Optimizing With Lagrange Multipliers

When a multivariable function f is to be maximized or minimized, the Lagrange multipliers method is a pretty common and easy tool to apply when the restrictions are in the form of equalities.

Consider three generators that can output xi megawatts, with i ranging from 1 to 3. The set of unknown variables is x1, x2, x3.

The cost of each generator is given by the formula


\displaystyle C_i=3x_i+(i)/(40)x_i^2

It means the cost for each generator is expanded as


\displaystyle C_1=3x_1+(1)/(40)x_1^2


\displaystyle C_2=3x_2+(2)/(40)x_2^2


\displaystyle C_3=3x_3+(3)/(40)x_3^2

The total cost of production is


\displaystyle C(x_1,x_2,x_3)=3x_1+(1)/(40)x_1^2+3x_2+(2)/(40)x_2^2+3x_3+(3)/(40)x_3^2

Simplifying and rearranging, we have the objective function to minimize:


\displaystyle C(x_1,x_2,x_3)=3(x_1+x_2+x_3)+(1)/(40)(x_1^2+2x_2^2+3x_3^2)

The restriction can be modeled as a function g(x)=0:


g: x_1+x_2+x_3=1000

Or


g(x_1,x_2,x_3)= x_1+x_2+x_3-1000

We now construct the auxiliary function


f(x_1,x_2,x_3)=C(x_1,x_2,x_3)-\lambda g(x_1,x_2,x_3)


\displaystyle f(x_1,x_2,x_3)=3(x_1+x_2+x_3)+(1)/(40)(x_1^2+2x_2^2+3x_3^2)-\lambda (x_1+x_2+x_3-1000)

We find all the partial derivatives of f and equate them to 0


\displaystyle f_(x1)=3+(2)/(40)x_1-\lambda=0


\displaystyle f_(x2)=3+(4)/(40)x_2-\lambda=0


\displaystyle f_(x3)=3+(6)/(40)x_3-\lambda=0


f_\lambda=x_1+x_2+x_3-1000=0

Solving for \lambda in the three first equations, we have


\displaystyle \lambda=3+(2)/(40)x_1


\displaystyle \lambda=3+(4)/(40)x_2


\displaystyle \lambda=3+(6)/(40)x_3

Equating them, we find:


x_1=3x_3


\displaystyle x_2=(3)/(2)x_3

Replacing into the restriction (or the fourth derivative)


x_1+x_2+x_3-1000=0


\displaystyle 3x_3+(3)/(2)x_3+x_3-1000=0


\displaystyle (11)/(2)x_3=1000


x_3=181.8\ MW

And also


x_1=545.5\ MW


x_2=272.7\ MW

The load balance
(x_1,x_2,x_3)=(545.5,272.7,181.8) Mw minimizes the total cost